QUESTION 221
Refer to the exhibit. Which two options describe possible causes of the failure shown in the exhibit? (Choose two.)
A. Two switches have the same zone set name, but different zone names and different zone members.
B. Two switches have the same zone set name and zone name, but different zone members.
C. The zoneset export interface command is used for the wrong interface.
D. The zoneset merge command can only be executed for VSAN 1.
E. The adjacent switch is down at the point of the zone merge.
Answer: AB
QUESTION 222
Given an E3 WAN link, which mode of compression would be the most appropriate choice?
A. Mode high
B. Mode medium
C. Mode low
D. Mode 1
E. Mode 2
Answer: D
QUESTION 223
Which three options describe information that can be captured with the show iscsi stats iscsi x/y detail command? (Choose three.)
A. PDU or frame drop occurrences
B. speed of the iSCSI interface
C. data CRC error
D. buffer credits
E. TMF-REQ and TMF-RESP
F. duplex of the iSCSI interface
Answer: ACE
QUESTION 224
Refer to the exhibit. When a CNA host connects to the virtual interface of the switch, what will happen?
A. The switch will not initialize because it is in the wrong mode.
B. The host will negotiate using DCBX and connect properly.
C. The host will negotiate using DCBX and will change parameters as required, but a shut/no shut is needed on the interface.
D. The host will not connect. The vFC port number does not match the Ethernet interface.
Answer: A
QUESTION 225
Which three options describe the key management control parameters that Cisco Prime DCNM provides? (Choose three.)
A. configuration of change control
B. single shared database for LAN and SAN configuration data
C. single point for integration with third-party test tools
D. ability to manage vPCs
E. autodiscovery of storage controllers
F. host driver management
G. support for script automation
Answer: ABD
QUESTION 226
Refer to the exhibit. What action must be taken to make fc1/1 capable of being an ISL port channel member operating at 4 GB?
A. One of the interfaces between fc1/2 and fc1/6 must be placed in out-of-service mode to free up bandwidth in the port group so that fc1/1 can use that bandwidth.
B. Interface fc1/1 must be placed into dedicated rate mode.
C. The B2B credit value of interface fc1/1 must be raised to a minimum of 100.
D. No action is necessary because shared rate mode ports are fine for ISLs.
E. No action is possible because module 1 is oversubscribed and will only support ISLs if the ports operate at 2GBs.
Answer: B
QUESTION 227
Which two statements about the FCIP Write Acceleration feature are true? (Choose two.)
A. WAN throughput is maximized by minimizing the impact of WAN latency for write operations.
B. The Write Acceleration feature does not have to be enabled on both sides of the FCIP link.
C. The FCIP Write Acceleration feature can only be used with multilink port channels if they are constructed with port channel protocol.
D. The Write Acceleration feature cannot be used across FSPF equal cost paths in FCIP deployments.
E. The Write Acceleration feature works by immediately returning the SCSI status on the initiator side of the FCIP link.
Answer: AD
QUESTION 228
Which statement best describes the Cisco Nexus 1000V Series?
A. The Cisco Nexus 1000V Series provides Layer 2 switching, advanced networking functions, and a common network management model in a virtualized server environment.
B. The Cisco Nexus 1000V Series provides Layer 3 switching, advanced networking functions, and a common network management model in a virtualized server environment.
C. The Cisco Nexus 1000V Series provides Layer 2 and Layer 3 switching, advanced networking functions, and a common network management model in a virtualized server environment.
D. The Cisco Nexus 1000V Series provides Layer 2 and Layer 3 switching but does not provide advanced networking functions or a common network management model in a virtualized server environment.
Answer: A
QUESTION 229
Which two statements about Cisco Nexus 1000V Series Switches are correct? (Choose two.)
A. When VSM interfaces are created for a virtual machine, the VMware vSwitch port-group configuration is used initially, which requires the creation of a port-group name for these interfaces and an appropriate VLAN. The simplest configuration is to create a single port group (for example, VSM-Interfaces), that includes all the interfaces that use this port group and the same VLAN.
B. The mgmt0 interface on the VSM does not necessarily require its own VLAN. In fact, you can use the same VLAN to which the VMware vCenter Server belongs. The VSM management VLAN is really no different from any other virtual machine data VLAN. Alternatively, network administrators can designate a special VLAN for network device management.
C. Always deploy the Cisco Nexus 1000V Series VSM in pairs, with one VSM that is defined as the primary module and the other that is defined as the secondary module on two separate hosts.
D. The service console is a critical interface that resides on every logical server.
Answer: BC
QUESTION 230
Which two methods can be used to install the Cisco Nexus 1000V VEM on an ESXi host? (Choose two.)
A. Installation using VMware Update Manager
B. Iinstallation via the esxupdate/esxcli command with a tar.gz file
C. Installation via the esxupdate/esxcli command with a .vib file
D. Copying VEM executable files to ESXi host /bin
E. Installation from the VSM using the vem install host command
F. Installation from the VSM using FTP and the vem auto-install command
Answer: AC
350-080 Updated Questions are 2015 Latest Released Which 100% will Meet in Your 350-080 Test! Braindump2go New Released 350-080 Exam Dumps Contain All New Added Questions Which Will Help you Have A Totally Success in 2015 New Tear! Download our 100% Pass Guaranteed 350-080 Exam Dumps Full Version, special 10% Off Discount enjoyed!